Dawell CZ DHC 6510R Portable Induction Heater

₺ 191.859,50

+ VAT
Product Code
: Dual-Lane High-Capacity 6510R
Add to Cart
PRODUCT DESCRIPTION PRODUCT REVIEWS

INVERTER
The DHC 6510R is designed for the controlled post-weld annealing of materials to reduce voltage and hydrogen content, as well as for pre-weld preheating up to 1050 °C. It features a temperature controller and data logging capabilities specifically for high-level programming of post-weld annealing.
programming specifically for welding annealing.
It also supports multi-zone mode, program linking and copying, setting multiple controller
values, and more. It has a recording duration of up to 1,400 hours.

 

*Energy
and petrochemical industries—pipelines, heat exchangers, boilers, steel
vessels, and flanges—for welding annealing and preheating—anywhere where welds require annealing.

*Framework
construction, shipbuilding—welding of long and short joints—preheating,
annealing.

*Mining
industries—preheating of parts prior to welding.

*Industrial
manufacturing—preheating parts to a specific temperature.

*Repairs,
renovations, welding work – proper preheating of parts for both economic and technological reasons,
mobility allows for the use of inverters on-site.

*Automotive
industry – preheating of the entire chassis prior to welding during production.

*Wide range of accessories.

 

Parameter

Value

Order
No.

04-004

Power
supply requirements

3x 400 V
+/- 15 %

Frequency
(Hz)

50/60 Hz

Power Consumption

23 A ±15
%

Ingress Protection
Code

IP21

Temperature
sensor

K-type
thermocouple, galvanically isolated

Inlet
protection

25 A

Output
voltage/current

0–60 V /
180 A, 65 V / 160 A, infinitely adjustable, CV/CC

Electrical
load

resistive
heating elements 24–60 V (type 30 / 42 / 60 V)

Measuring/control
range

-25° to
1,200 °C

Alarm

2
configurable (deviation from setpoint/actual value, reaching a specific temperature, etc.)

Fault
detection

thermocouple
disconnection, overload, overheating, output short circuit, etc.

Multizone
control

Yes, master/slave
type, up to 9 units

Operating
Temperatures / Range

-20° to
40°C (with power limitation up to 50 °C)

Regulator

Digital,
user-adjustable

Recorder

up to
1,400 hours of recording; also stores error conditions

Data
download

via
485/USB to PC, export to Excel

Dimensions

170x370x405
mm

Height

17 kg

 

 

 

Portable—weighs 17 kg.

Even heating.

Power: 10.8 kW.

Can be connected to up to 4 elements.

Flexible use – power supply: 3x
400 V, 32 A.

Intuitive and easy controls – easy to use.

Multi-zone mode – connect up to 9
machines with a single application – heating control for zones with a total power output of up to 95 kW. Versatile applications – even heating.

3-in-1 – inverter + temperature
regulator + data logger.

 

DHC 6510R controller and data logger – easy programming of the controller.

 

Quick data download from the data logger and easy work with measured data.
Temperature can be controlled using any of 20 temperature profiles/programs—each with up to 180 segments—that are user-configurable, or by a temperature set directly by the user that can be changed at any time as needed.
temperature that can be changed at any time as needed. You can independently set the heating or cooling rate, the duration for which the temperature must be maintained, and the target temperature in each profile segment, as well as in manual temperature control mode.

 

Of course, the heating power can be controlled directly. The controller features a user lock in the menu to lock the PID
settings. A digital recorder for the heating curve with a 64-hour
recording capacity is also integrated.
The data can be transferred to a PC where it can be further
processed—for example, to record the heating profile or control data. Thus, this device offers maximum
complexity and ease of use, allowing anyone to
operate it.

No comments yet.